Transfer sluice

The active transfer sluice allows the transfer of raw materials between rooms with different cleanliness classes.

Advantages of the model

  • The gateway doors can be opened and closed both mechanically and with the help of electromagnetic locks;
  • air intake into the airlock chamber is carried out from the side of the high-class room, air extraction from the airlock chamber is carried out through perforations in the lower part of the airlock chamber.
  • air intake is carried out through the perforations in the lower part of the door to the low-class room
  • the door of the airlock chamber is made of the "sandwich" type
  • the doors are equipped with double-glazed windows for visualisation of the interior of the airlock.
Specifications

Overall dimensions LxWxH, mm:

  • 800x950x1997

Materials:

  • chamber material - AISI304 steel, s - 1.0 mm, 1.2 mm, 1.5 mm
  • frame pipe AISI304 steel - 30x10x1.5 mm, 40x20x1.2 mm, 20x20x1.2 mm
  • external lining of the gateway - material steel St3, powder paint RAL 9003.

Complete set of the bypass gateway:

  • EBM-PAPST motor - 2 pcs.
  • HEPA fine filter of H13 class - 2 pcs.
  • pre-filter F7 - 2 pcs.
  • diffuser - Magnehelic - 1 pc.

Control / automation of the gateway:

  • gateway control unit - Siemens Logo
  • locking system for simultaneous door opening with light and sound alarm
  • control unit for purging time and door locking during purging.